A drip line opens with a solenoid valve, just like a sprinkler line. The difference is behind the valve. Flow is low. Run time is long. Water is not visible on the surface. These three differences change how the automation is set up.

Why is automation different on drip?

  • Low flow, long run time. Emitters deliver a few litres an hour. To apply the same water, the line stays open longer. The schedule is built accordingly.
  • Faults are invisible. On sprinklers a broken pipe leaves a puddle on the lawn. On drip a blocked emitter or a cut line leaves no mark on the surface. It shows when the plant dries out; by then it is late.
  • Clogging risk. Emitter openings are small. A filter and a pressure regulator sit at the head of the line. When the filter fills, flow drops.
  • Wind does not matter. Water goes straight to the soil. A wind rule does not hold a drip line back. Efficiency is high; no efficiency allowance is added to the duration.

Installation: existing line, existing valve

The solenoid valve at the head of the drip line stays in place. So do the filter and the pressure regulator. The LND-1 / LND-2 battery controller goes into the valve box, next to the solenoid. The solenoid wires connect to the controller. It works with DC latching solenoids. The batteries go in: 2 × 9 V. No cable is laid and no power line is needed. The housing is rated IP67; it withstands the water and dust in a valve box.

The first setup is done from a phone over Bluetooth. For remote management, the ESTRON BLE-LoRa version and one LoRaWAN gateway on site are enough. In a small single-line garden, the Bluetooth-only BLE version runs a fixed schedule. How the valve opens: what is a solenoid valve and how does it work?

Schedule: the drip line is its own line

A drip line does not share a schedule with a sprinkler line. Shrubs and tree bases are watered rarely and for a long time; twice a week for 45 minutes, for example. A flower bed wants it more often. Every line gets its own window, duration and days. The steps: how to build an irrigation schedule.

In AI mode the duration is recalculated every day. The plant's daily water use (ETc) is found with the FAO-56 method. Rainfall is subtracted. The result is a percentage of the reference duration. On a windy night the sprinkler line waits while the drip line waters; the decision is made per line. Details: how does the AI make the irrigation decision?

Flow monitoring: the most valuable data on drip

A flow sensor or water meter connects to the pulse input of LND-1. The expected flow of a drip line is low and steady. A deviation tells the fault:

MeasuredLikely causeIn the panel
Flow lower than expectedFull filter, blocked emitters, crushed lineLow-flow alarm
Flow higher than expectedCut line, missing emitter, open endHigh-flow alarm
Flow while the valve is closedValve not closing, leakLeak alarm

The alarm arrives in the mobile app, by e-mail or by SMS. The crew goes to the site with a diagnosis, not a symptom. The method: catch water leaks without visiting the site. LND-2 has no pulse input; it manages two valves and does not measure flow. A drip line that needs flow monitoring gets an LND-1.

Drip and sprinklers side by side

Drip lineSprinkler line
FlowLowHigh
Run timeLong, infrequentShort, more frequent
Wind ruleNo effectPostpones
Efficiency allowanceNone10–25%
Fault signNone on the surface; flow tellsPuddle, spray
ControllerThe same: LND-1 / LND-2, same panel, separate line

Where is it used?

Drip is common on narrow medians; sprinklers on wide ones. Both sit side by side on one boulevard: median irrigation. In a park, shrub groups and tree bases are watered by drip. In a residential complex, flower beds and the strips in front of the blocks are drip lines. The xeriscape decree asks for pressurised, automated irrigation; drip meets that definition: the xeriscape decree.

At the end of the season the drip lines are drained; the controller stays in the valve box. Steps: how to winterize an irrigation system. Multi-site installations: irrigation automation for landscaping companies. ESTRON is made in Türkiye; hardware and software are developed locally.

In short: the drip line keeps its existing solenoid valve; the battery controller is fitted next to it. The line gets its own schedule: long and infrequent. A wind rule does not hold drip back. A flow sensor (LND-1) shows blockages and cut lines without a site visit.

Frequently asked

Does every drip line need its own controller?

Every solenoid valve needs one output. LND-1 manages one valve, LND-2 two. Two neighbouring drip lines run on a single LND-2.

Does the controller regulate pressure?

No. The controller opens and closes the valve. The pressure regulator and the filter are parts of the drip line itself; they stay in place.

How do I know a line is blocked?

With the flow sensor connected to LND-1. When flow drops below the expected value, an alarm appears in the panel. Without a flow sensor, the sign shows in the plants. Other questions are on the FAQ page.